Endress+Hauser Proline Promag W 400 electromagnetic flowmeter

Versatile standard flowmeter for the water and wastewat…

Category: E+H  ·  Model: Contact us

Description

Versatile standard flowmeter for the water and wastewater industry

Specification

Measuring principle Electromagnetic
Product headline
Versatile Standard Flowmeter for Water and Wastewater Industry
Reliable Measurement at Constant Accuracy with 0 x DN Inlet Run and No Pressure Loss
Ideal for Water Measurement Applications (Drinking Water, Utility Water, Industrial/Municipal Wastewater)
Sensor features Flexible Engineering with Fixed or Lap-Joint Process Connections
Application Fitness with EN ISO 12944 Corrosion Protection for Underground or Underwater Installation
Improved Plant Availability with Sensor Compliant to Industry-Specific Requirements
International Drinking Water Approvals
Degree of Protection IP68 (Type 6P Enclosure)
Approved for Custody Transfer to MI-001/OIML R49
Transmitter features Safe Operation with Display, Touch Control, and Background Lighting
Time-Saving Local Operation via Integrated Web Server
Integrated Verification with Heartbeat Technology
Transmitter Housing: Polycarbonate or Aluminum
WLAN Access
Integrated Data Logger for Measured Values Monitoring
Nominal diameter range DN 25 to 3000(1 to 120″)
Wetted materials Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum
Measured variables Volume flow, conductivity, mass flow
Max. measurement error Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec
Measuring range 0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
Max. process pressure PN 40, Class 300, 20K
Medium temperature range Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Ambient temperature range Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Sensor housing material DN 25 to 300 (1 to 12″): AlSi10Mg, coated
DN 25 to 2000 (1 to 78″): Carbon steel with protective varnish
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): Polycarbonate
Transmitter housing material Polycarbonat; AlSi10Mg, coated
Degree of protection Compact version: IP66/67, type 4X enclosure
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure, with protective varnish
according to EN ISO 12944 C5‐M/Im1/Im2/Im3
Transmitter remote version: IP66/67, Type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside)
Configuration via local display, web browser and operating tools possible
Outputs 3 ouputs:
0‐20 mA/4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Pulse/frequency output (passive)
Switch output (passive)
Inputs Status input
Digital communication HART, PROFIBUS DP, EtherNet/IP, Modbus RS485
Power supply AC 100…240 V / AC/DC 24 V
Hazardous area approvals cCSAus
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Custody transfer according to MI‐001 or OIML R49 (optional class I in combination with 0DN inlet run)
Pressure approvals and certificates CRN
Material certificates 3.1 material
Hygienic approvals and certificates
Sanitary approval: 3-A, EHEDG, seals acc. to FDA